Metal halide lamp with quartz burner , HRI-TS 2000W/D/S/400/K12S

Article No.: 32418615

Metal halide lamp with quartz burner , HRI-TS 2000W/D/S/400/K12S

Mobile Menu

  • Company
  • UV Lamps
  • IR Lamps
  • Product Catalogue
  • Service & Contact

Breadcrumb

  1. Product Catalogue
  2. Special Lamps visible light
  3. HID Lamps for Solar Simulation
  4. Products
Metal halide short arc lamp clear, daylight, high luminous flux, base K12s. Operation in enclosed luminaire, with ballast and (hot restrike)ignitor.
  • Add to compare
  • PDF download
  • 1,950.0 W
  • 2000 W
  • 210000 lm
  • 6100 K
  • 4500 h
  • Tube, double-ended
  • Active

Image Gallery

Produktbild - Metal halide lamp with quartz burner , HRI-TS 2000W/D/S/400/K12S
Produktbild - Metal halide lamp with quartz burner , HRI-TS 2000W/D/S/400/K12S
Zeichnung - Metal halide lamp with quartz burner , HRI-TS 2000W/D/S/400/K12S
Energielabel - Metal halide lamp with quartz burner , HRI-TS 2000W/D/S/400/K12S
Picto Picto Picto Picto

General Data

32418615
HRI-TS 2000W/D/S/400/K12S
4008597186158
10
4008597486159
1.446
0.39
0.158
0.258
61 g
Active

Electric Parameters

1950.0 W
2000 W
220-230 V
190 V
400 V
4.0 up to 5.0
36 kV
11.3 A
10.3 A
60 µF
190%
Daelay-action; min. double nominal current
No
No

Light Application Parameters

210000 lm
210000 lm
108 lm/W
100 lm/W
daylight
6100 K
83
83
0.95
0.90

Service Life

4500 h
1800 h
0.94
0.76
0.47

Specification

no Label needed (> 82.000 lm)
A+
36 mm
187 mm
187 mm
41 mm
p15
180.0 mg
Tube, double-ended
Clear
K12s-36
White

Notes on Operation

p15

Information especially for EPREL

no Label needed (> 82.000 lm)
MH

Miscellaneous

32416491

Notes

Base

Sockel-ZeichnungK12s-36
IEC/EN 60061-1
Sheet 7004-168-1

Spectrum

Natural daylight is a mixture of direct sunlight and the light of the sky. Therefore, its spectral composition changes permanently due to the changing time of day. The standardised light classification D65 corresponds to a daylight with a colour temperature of approximately 6500 K.
Every discharge lamp type has got an individual spectral power distribution according to its chemical filling. From this result important properties light colour or colour rendering.
Should the spectral lines be very close together the lamp presumably has got a very good colour rendering index, so, Ra might be near 100. Does the spectrum rather look like single lines or frayed out the colour rendering of the lamp will probably be not as good.
If number and height of the spectral lines within the blue range (around 400 nm) prevails it might be a lamp with a rather cold light colour like for example daylight. On the other hand, should the red (around 700 nm) or the red and yellow (around 600 nm) range be dominant one can assume that the lamp will be a rather warm light colour like WDL.
After the lamp start a metal hlide lamp needs about 2-4 minutes time to reach its full luminous flux, all colours in the spectrum are within the discharge arc then.
Visible region from 380 to 780 nm; height of graph corresponding with relative spectral emission (400mW/klm) per 10nm.

Spektrum 1HRI.../D

Spektrum 2daylight(D 65)

Circuit diagram(s)

Schaltbild1Standard circuit HID with external ignitor
Key:
L. = lamp
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor
Z = ignitor

The required control gear (here ignitor and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2Circuit for 400V-HID-lamps suitable for hot restrike
Key:
L. = lamp
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor
Z = ignitor

S = fuse

The required control gear (here fuse, capacitor, ignitor and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2Circuit for 400V-HID-lamps suitable for hot restrike
Key:
L. = lamp
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor
Z = ignitor

S = fuse

The required control gear (here fuse, capacitor, ignitor and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Schaltbild2Circuit for 400V-HID-lamps suitable for hot restrike
Key:
L. = lamp
VG = electromagnetic ballast (KVG/VVG)
P = phase
N = zero potential
K = p. f. correction capacitor
Z = ignitor

S = fuse

The required control gear (here fuse, capacitor, ignitor and ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.

Special features

Picto Picto Picto Picto

General notes

The technical design data in accordance with DIN and IEC. The producer does not take any responsibility for damage to persons or property in case of unsuitable operation or handling of the product. Operating data and dimensions are valid within the usual tolerances. Related lamp types (different bases, mains voltages) may be available on request. Sale and delivery are effected in accordance with the Radium Terms of Delivery and Payment valid on the day of conclusion of contract. Packing units offer economical advantages to the purchase and logistic department. Please match your quantity volume accordingly. For orders of a minimum quantity (clefts) with a lamp model the amount lower than the volume of each packaging unit, we will invoice 10 % additional charge per lamp type. Technical changes and terms of delivery are reserved. Manipulation of any kind to packaging or product is not permissible as this will violate Radium brand rights. Furthermore, technical properties of the product can change to its disadvantage or even destruction. Therefore, Radium cannot be responsible for consequential damages.
® = Registered trademark
Subject to change without notice. Errors and omissions excepted.


Downloads

TI - Data/ complete
Declaration of Conformity
User Instruction

Passende Produkte

Similar Products

Compare products

Compare products or see the products that have been saved to comparison.

More

News

XERADEX® Module

Compact XERADEX® Module XIS-250

14.06.2024 - Coming soon

Ideal for test facilities and for applications in smaller areas:

Radium will launch a complete compact module for…

BSFZ seal

Radium receives BSFZ seal of approval.

24.05.2024 - A sign of innovative strength.

We are pleased to announce that Radium has been awarded the BSFZ seal of approval (Bescheinigungsstelle Forschungszulage) by…

Read more

Footer

  • © Radium 2025
  • Imprint
  • Data Protection
  • www.radium.de
  • Terms of Use
  • Delivery and Payment Terms
  • Cookie Policy
  • Purchasing Conditions
  • Export Control Clause